Air flow management in raised floor ...
~
Arghode, Vaibhav K.
Air flow management in raised floor data centers[electronic resource] /
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
杜威分類號:
697.9316
書名/作者:
Air flow management in raised floor data centers/ by Vaibhav K. Arghode, Yogendra Joshi.
作者:
Arghode, Vaibhav K.
其他作者:
Joshi, Yogendra.
出版者:
Cham : : Springer International Publishing :, 2016.
面頁冊數:
xx, 72 p. : : ill. (some col.), digital ;; 24 cm.
Contained By:
Springer eBooks
標題:
Data processing service centers - Cooling.
標題:
Data processing service centers - Energy conservation.
標題:
Heat - Transmission.
標題:
Air flow.
標題:
Buildings - Environmental engineering.
標題:
Engineering.
標題:
Facility Management.
標題:
Energy Efficiency (incl. Buildings)
標題:
Engineering Thermodynamics, Heat and Mass Transfer.
標題:
Computer Hardware.
ISBN:
9783319258928
ISBN:
9783319258904
內容註:
1. Introduction -- 2. Metrology Tools -- 3. Cooling Air Delivery Through Perforated Tiles -- 4. Cold Aisle Containment -- 5. Other Air Delivery Schemes.
摘要、提要註:
The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.
電子資源:
http://dx.doi.org/10.1007/978-3-319-25892-8
Air flow management in raised floor data centers[electronic resource] /
Arghode, Vaibhav K.
Air flow management in raised floor data centers
[electronic resource] /by Vaibhav K. Arghode, Yogendra Joshi. - Cham :Springer International Publishing :2016. - xx, 72 p. :ill. (some col.), digital ;24 cm. - SpringerBriefs in applied sciences and technology,2191-530X. - SpringerBriefs in applied sciences and technology..
1. Introduction -- 2. Metrology Tools -- 3. Cooling Air Delivery Through Perforated Tiles -- 4. Cold Aisle Containment -- 5. Other Air Delivery Schemes.
The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.
ISBN: 9783319258928
Standard No.: 10.1007/978-3-319-25892-8doiSubjects--Topical Terms:
469101
Data processing service centers
--Cooling.
LC Class. No.: TJ163.5.D38
Dewey Class. No.: 697.9316
Air flow management in raised floor data centers[electronic resource] /
LDR
:02137nam a2200325 a 4500
001
454978
003
DE-He213
005
20160722103142.0
006
m d
007
cr nn 008maaau
008
161227s2016 gw s 0 eng d
020
$a
9783319258928
$q
(electronic bk.)
020
$a
9783319258904
$q
(paper)
024
7
$a
10.1007/978-3-319-25892-8
$2
doi
035
$a
978-3-319-25892-8
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TJ163.5.D38
072
7
$a
KJMV4
$2
bicssc
072
7
$a
BUS093000
$2
bisacsh
082
0 4
$a
697.9316
$2
23
090
$a
TJ163.5.D38
$b
A691 2016
100
1
$a
Arghode, Vaibhav K.
$3
652941
245
1 0
$a
Air flow management in raised floor data centers
$h
[electronic resource] /
$c
by Vaibhav K. Arghode, Yogendra Joshi.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2016.
300
$a
xx, 72 p. :
$b
ill. (some col.), digital ;
$c
24 cm.
490
1
$a
SpringerBriefs in applied sciences and technology,
$x
2191-530X
505
0
$a
1. Introduction -- 2. Metrology Tools -- 3. Cooling Air Delivery Through Perforated Tiles -- 4. Cold Aisle Containment -- 5. Other Air Delivery Schemes.
520
$a
The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers.
650
0
$a
Data processing service centers
$x
Cooling.
$3
469101
650
0
$a
Data processing service centers
$x
Energy conservation.
$3
469102
650
0
$a
Heat
$x
Transmission.
$3
382398
650
0
$a
Air flow.
$3
467389
650
0
$a
Buildings
$x
Environmental engineering.
$3
417333
650
1 4
$a
Engineering.
$3
372756
650
2 4
$a
Facility Management.
$3
465518
650
2 4
$a
Energy Efficiency (incl. Buildings)
$3
464633
650
2 4
$a
Engineering Thermodynamics, Heat and Mass Transfer.
$3
463870
650
2 4
$a
Computer Hardware.
$3
465514
700
1
$a
Joshi, Yogendra.
$3
469099
710
2
$a
SpringerLink (Online service)
$3
463450
773
0
$t
Springer eBooks
830
0
$a
SpringerBriefs in applied sciences and technology.
$3
463858
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-25892-8
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
多媒體
多媒體檔案
http://dx.doi.org/10.1007/978-3-319-25892-8
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入