A non-invasive fluorescence-based ox...
~
Buchapudi, Koutilya Reddy.
A non-invasive fluorescence-based oxygen sensor and platform for studying cell responses to metabolic agents in real-time.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
書名/作者:
A non-invasive fluorescence-based oxygen sensor and platform for studying cell responses to metabolic agents in real-time.
作者:
Buchapudi, Koutilya Reddy.
面頁冊數:
93 p.
附註:
Source: Dissertation Abstracts International, Volume: 77-04(E), Section: B.
Contained By:
Dissertation Abstracts International77-04B(E).
標題:
Biomedical engineering.
標題:
Optics.
標題:
Biology.
ISBN:
9781339283135
摘要、提要註:
A fluorescence-based sensor in a transverse flow/stop measurement platform has been developed to determine real-time changes in oxygen consumption rates for cell metabolic studies. The oxygen sensitive fluorophore platinum octaethylporphyrin was embedded in a cellulose acetate matrix and affixed to a fiber optic bundle, which provided for transmission of the excitation and emission wavelengths of the film. The fiber optic bundle was sealed in a sensor head that can be used in standard 24-well plates common to research labs. The utility of the sensor and sensing platform were determined by measuring the changes in oxygen consumption rates of Candida albicans during 90/30 s flow/stop cycles. Exposure of these cells to metabolic antagonists and an enhancer showed the expected decrease and increase in oxygen consumption rates in real time. The applicability of the platform to biological studies is illustrated by determination of synergistic activities between antifungal drugs and fluoride exposure in Candida albicans. The robustness of the fluorophore film is demonstrated by perfusion with different media and analyte conditions in the absence of cells. For stop cycle time intervals less than 1 minute the sensor exhibited a rapid and fairly linear change in fluorescence intensity to changing oxygen concentrations in the measurement chamber. Flow cycle fluorescence intensities were used as a baseline correction for treating the stop cycle fluorescence peaks.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3664523
A non-invasive fluorescence-based oxygen sensor and platform for studying cell responses to metabolic agents in real-time.
Buchapudi, Koutilya Reddy.
A non-invasive fluorescence-based oxygen sensor and platform for studying cell responses to metabolic agents in real-time.
- 93 p.
Source: Dissertation Abstracts International, Volume: 77-04(E), Section: B.
Thesis (Ph.D.)--Louisiana Tech University, 2015.
A fluorescence-based sensor in a transverse flow/stop measurement platform has been developed to determine real-time changes in oxygen consumption rates for cell metabolic studies. The oxygen sensitive fluorophore platinum octaethylporphyrin was embedded in a cellulose acetate matrix and affixed to a fiber optic bundle, which provided for transmission of the excitation and emission wavelengths of the film. The fiber optic bundle was sealed in a sensor head that can be used in standard 24-well plates common to research labs. The utility of the sensor and sensing platform were determined by measuring the changes in oxygen consumption rates of Candida albicans during 90/30 s flow/stop cycles. Exposure of these cells to metabolic antagonists and an enhancer showed the expected decrease and increase in oxygen consumption rates in real time. The applicability of the platform to biological studies is illustrated by determination of synergistic activities between antifungal drugs and fluoride exposure in Candida albicans. The robustness of the fluorophore film is demonstrated by perfusion with different media and analyte conditions in the absence of cells. For stop cycle time intervals less than 1 minute the sensor exhibited a rapid and fairly linear change in fluorescence intensity to changing oxygen concentrations in the measurement chamber. Flow cycle fluorescence intensities were used as a baseline correction for treating the stop cycle fluorescence peaks.
ISBN: 9781339283135Subjects--Topical Terms:
218538
Biomedical engineering.
A non-invasive fluorescence-based oxygen sensor and platform for studying cell responses to metabolic agents in real-time.
LDR
:02413nam a2200289 4500
001
440957
005
20160422125037.5
008
160525s2015 ||||||||||||||||| ||eng d
020
$a
9781339283135
035
$a
(MiAaPQ)AAI3664523
035
$a
AAI3664523
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Buchapudi, Koutilya Reddy.
$3
629977
245
1 2
$a
A non-invasive fluorescence-based oxygen sensor and platform for studying cell responses to metabolic agents in real-time.
300
$a
93 p.
500
$a
Source: Dissertation Abstracts International, Volume: 77-04(E), Section: B.
500
$a
Adviser: Sven Eklund.
502
$a
Thesis (Ph.D.)--Louisiana Tech University, 2015.
520
$a
A fluorescence-based sensor in a transverse flow/stop measurement platform has been developed to determine real-time changes in oxygen consumption rates for cell metabolic studies. The oxygen sensitive fluorophore platinum octaethylporphyrin was embedded in a cellulose acetate matrix and affixed to a fiber optic bundle, which provided for transmission of the excitation and emission wavelengths of the film. The fiber optic bundle was sealed in a sensor head that can be used in standard 24-well plates common to research labs. The utility of the sensor and sensing platform were determined by measuring the changes in oxygen consumption rates of Candida albicans during 90/30 s flow/stop cycles. Exposure of these cells to metabolic antagonists and an enhancer showed the expected decrease and increase in oxygen consumption rates in real time. The applicability of the platform to biological studies is illustrated by determination of synergistic activities between antifungal drugs and fluoride exposure in Candida albicans. The robustness of the fluorophore film is demonstrated by perfusion with different media and analyte conditions in the absence of cells. For stop cycle time intervals less than 1 minute the sensor exhibited a rapid and fairly linear change in fluorescence intensity to changing oxygen concentrations in the measurement chamber. Flow cycle fluorescence intensities were used as a baseline correction for treating the stop cycle fluorescence peaks.
590
$a
School code: 0109.
650
4
$a
Biomedical engineering.
$3
218538
650
4
$a
Optics.
$3
183779
650
4
$a
Biology.
$3
171887
690
$a
0541
690
$a
0752
690
$a
0306
710
2
$a
Louisiana Tech University.
$3
423333
773
0
$t
Dissertation Abstracts International
$g
77-04B(E).
790
$a
0109
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3664523
筆 0 讀者評論
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3664523
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入