語系:
繁體中文
English
日文
簡体中文
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Analysis and evaluation of stormwate...
~
Colorado State University.
Analysis and evaluation of stormwater quantity and quality performance for three permeable pavement systems in Fort Collins, Colorado.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
書名/作者:
Analysis and evaluation of stormwater quantity and quality performance for three permeable pavement systems in Fort Collins, Colorado.
作者:
Gruber, Eli.
面頁冊數:
146 p.
附註:
Source: Masters Abstracts International, Volume: 52-01.
Contained By:
Masters Abstracts International52-01(E).
標題:
Water Resource Management.
標題:
Engineering, Environmental.
ISBN:
9781303153464
摘要、提要註:
Urbanization and the subsequent increase of effective impervious area (EIA) result in an increase in storm runoff volumes, peak flow rates and pollutant concentrations. Stormwater management has recently shifted towards a focus on site level low impact development (LID) techniques that aim to reduce the total stormwater runoff volumes in addition to attenuating peak flows and removing pollutants at or near the source of runoff. Permeable pavement systems (PPS) are a subset of LID stormwater best management practices (BMPs) of particular interest in dense urban areas because they can be installed in parking areas and low traffic roadways where the availability of land space for more traditional BMPs is not available. However, few studies have documented the performance of PPS in terms of reducing runoff volume, peak flow and pollutant loads in semi-arid environments such as Colorado. Such information is necessary to improve the selection of BMP/LIDs for stormwater management.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1539630
Analysis and evaluation of stormwater quantity and quality performance for three permeable pavement systems in Fort Collins, Colorado.
Gruber, Eli.
Analysis and evaluation of stormwater quantity and quality performance for three permeable pavement systems in Fort Collins, Colorado.
- 146 p.
Source: Masters Abstracts International, Volume: 52-01.
Thesis (M.S.)--Colorado State University, 2013.
Urbanization and the subsequent increase of effective impervious area (EIA) result in an increase in storm runoff volumes, peak flow rates and pollutant concentrations. Stormwater management has recently shifted towards a focus on site level low impact development (LID) techniques that aim to reduce the total stormwater runoff volumes in addition to attenuating peak flows and removing pollutants at or near the source of runoff. Permeable pavement systems (PPS) are a subset of LID stormwater best management practices (BMPs) of particular interest in dense urban areas because they can be installed in parking areas and low traffic roadways where the availability of land space for more traditional BMPs is not available. However, few studies have documented the performance of PPS in terms of reducing runoff volume, peak flow and pollutant loads in semi-arid environments such as Colorado. Such information is necessary to improve the selection of BMP/LIDs for stormwater management.
ISBN: 9781303153464Subjects--Topical Terms:
423292
Water Resource Management.
Analysis and evaluation of stormwater quantity and quality performance for three permeable pavement systems in Fort Collins, Colorado.
LDR
:05385nam a2200337 4500
001
404503
005
20140528124254.5
008
140703s2013 ||||||||||||||||| ||eng d
020
$a
9781303153464
035
$a
(MiAaPQ)AAI1539630
035
$a
AAI1539630
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Gruber, Eli.
$3
565583
245
1 0
$a
Analysis and evaluation of stormwater quantity and quality performance for three permeable pavement systems in Fort Collins, Colorado.
300
$a
146 p.
500
$a
Source: Masters Abstracts International, Volume: 52-01.
500
$a
Adviser: Larry A. Roesner.
502
$a
Thesis (M.S.)--Colorado State University, 2013.
520
$a
Urbanization and the subsequent increase of effective impervious area (EIA) result in an increase in storm runoff volumes, peak flow rates and pollutant concentrations. Stormwater management has recently shifted towards a focus on site level low impact development (LID) techniques that aim to reduce the total stormwater runoff volumes in addition to attenuating peak flows and removing pollutants at or near the source of runoff. Permeable pavement systems (PPS) are a subset of LID stormwater best management practices (BMPs) of particular interest in dense urban areas because they can be installed in parking areas and low traffic roadways where the availability of land space for more traditional BMPs is not available. However, few studies have documented the performance of PPS in terms of reducing runoff volume, peak flow and pollutant loads in semi-arid environments such as Colorado. Such information is necessary to improve the selection of BMP/LIDs for stormwater management.
520
$a
Three PPS in Fort Collins, Colorado were monitored between 2009 and 2011 to evaluate pollutant reduction, runoff volume reduction performance and surface infiltration rates. The Mountain and Walnut permeable inter-locking concrete paver (PICP) sites, referred to collectively as Mitchell Block, were each designed with differing "no-infiltration" sub-base designs to compare performance between a system with a sand filter layer (Walnut) and one with only gravel layers (Mountain). The third site, referred to as CTL, is a porous concrete (PC) parking lot that allows full infiltration, and was only monitored for water quality and surface infiltration rates.
520
$a
Mountain, Walnut and CTL all had lower effluent median event mean concentrations (EMCs) than those found at two Fort Collins stormwater outfalls for; total suspended solids (TSS), total recoverable zinc (TR Zn), total phosphorous (TP), total nitrogen (TN), total organic nitrogen (TON), total Kjeldahl nitrogen (TKN) and ammonia (NH3). EMCs for TR copper (Cu), nitrate (NO3) and total dissolved solids (TDS) at all three sites were elevated compared to the outfall sites. The TR Cu result EMCs at the three PPS were elevated compared to effluent PPS data from the International Stormwater BMP Database, which may indicate higher source concentrations in these study areas. CTL had elevated TR chromium (Cr) concentrations, which is likely a function of the portland cement in the PC itself, leaching Cr into the exfiltrate. Walnut had lower effluent median EMCs for 10 of the 13 water quality parameters analyzed, including significantly lower concentrations for TON, TKN and TR Cu.
520
$a
Recorded effluent volumes and estimated influent volumes to the PPS at the Mitchell Block sites were used to calculate runoff volume reduction on an event-based and long-term basis. Both sites provided runoff reduction for over 70% of the monitored events, with Mountain and Walnut reducing 45% and 35% of the total runoff volume monitored at each site, respectively. These results confirm that "no-infiltration" PPS designs are capable of reducing large volumes of storm runoff. Field capacity (water retention capacity) of the two sites was investigated with regard to runoff reduction. Runoff volume reduction at Mountain exceeded the field capacity for the two longest storms monitored. This suggests that runoff volume reduction potential can exceed field capacity given long intermittent rainfall events. An investigation of hydrologic storm parameters indicated a discernible trend between runoff volume reduction and antecedent dry time, showing increasing runoff volume reduction with increasing antecedent dry time.
520
$a
The runoff volume reduction performance at Mountain was greater than Walnut based on 23% greater median and average volume reduction per storm in addition to 25% greater total aggregate volume reduction for common monitored events at the two sites. This study did not investigate the design characteristics that allowed Mountain to provide greater runoff volume reduction.
520
$a
Surface infiltration rates at all three sites were estimated using a single infiltrometer field test. The results indicated that sections of all three sites are experiencing varying degrees of clogging. CTL had the highest degree of clogging, with two of the three tests indicating zero infiltration. Maintenance is recommended to reduce clogging for all three sites.
590
$a
School code: 0053.
650
4
$a
Water Resource Management.
$3
423292
650
4
$a
Engineering, Environmental.
$3
422942
690
$a
0595
690
$a
0775
710
2
$a
Colorado State University.
$b
Civil and Environmental Engineering.
$3
565581
773
0
$t
Masters Abstracts International
$g
52-01(E).
790
$a
0053
791
$a
M.S.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1539630
筆 0 讀者評論
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1539630
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入