Effective Daylighting: Evaluating Da...
~
Konis, Kyle Stas.
Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
書名/作者:
Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants.
作者:
Konis, Kyle Stas.
面頁冊數:
420 p.
附註:
Source: Dissertation Abstracts International, Volume: 73-07(E), Section: B, page: .
Contained By:
Dissertation Abstracts International73-07(E)B.
標題:
Psychology, Behavioral.
標題:
Engineering, Architectural.
標題:
Architecture.
ISBN:
9781267228406
摘要、提要註:
Commercial office buildings promoted as "sustainable," "energy efficient," "green," or "high performance" often reference use of daylight as a key strategy for reducing energy consumption and enhancing indoor environmental quality. However, buildings are rarely studied in use to examine if the design intent of a sufficiently daylit and a visually comfortable work environment is achieved from the perspective of building occupants or how occupant use of shading devices may affect electrical lighting energy reduction from photocontrols. This dissertation develops a field-based approach to daylighting performance assessment that pairs repeated measures of occupant subjective response using a novel desktop polling station device with measurements of the physical environment acquired using High Dynamic Range (HDR) imaging and other environmental sensors with the objective of understanding the physical environmental conditions acceptable to occupants. The approach is demonstrated with a 6-month field study involving (N=44) occupants located in perimeter and core open-plan office spaces in the San Francisco Federal Building (SFFB). Over 23,100 subjective assessments paired with physical measures were analyzed to develop models of visual discomfort and shade control and to examine the assumptions of existing daylighting performance indicators. The analysis found that existing daylight performance indicators overestimated the levels of daylight illuminance required by occupants to work comfortably without overhead ambient electrical lighting. Time-lapse observation of interior roller shades showed that existing shade control models overestimated the frequency of shade operation and underestimated the level of facade occlusion due to interior shades. Comparison of measured results to the daylighting objectives of the SFFB showed that available daylight enabled electrical lighting energy reduction in the perimeter zones but not in the open-plan core zones. The results extend existing knowledge regarding the amount of daylight illuminance acceptable for occupants to work comfortably without overhead electrical lighting and for the physical variables (and stimulus intensities) associated with visual discomfort and the operation of interior shading devices.
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3498998
Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants.
Konis, Kyle Stas.
Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants.
- 420 p.
Source: Dissertation Abstracts International, Volume: 73-07(E), Section: B, page: .
Thesis (Ph.D.)--University of California, Berkeley, 2011.
Commercial office buildings promoted as "sustainable," "energy efficient," "green," or "high performance" often reference use of daylight as a key strategy for reducing energy consumption and enhancing indoor environmental quality. However, buildings are rarely studied in use to examine if the design intent of a sufficiently daylit and a visually comfortable work environment is achieved from the perspective of building occupants or how occupant use of shading devices may affect electrical lighting energy reduction from photocontrols. This dissertation develops a field-based approach to daylighting performance assessment that pairs repeated measures of occupant subjective response using a novel desktop polling station device with measurements of the physical environment acquired using High Dynamic Range (HDR) imaging and other environmental sensors with the objective of understanding the physical environmental conditions acceptable to occupants. The approach is demonstrated with a 6-month field study involving (N=44) occupants located in perimeter and core open-plan office spaces in the San Francisco Federal Building (SFFB). Over 23,100 subjective assessments paired with physical measures were analyzed to develop models of visual discomfort and shade control and to examine the assumptions of existing daylighting performance indicators. The analysis found that existing daylight performance indicators overestimated the levels of daylight illuminance required by occupants to work comfortably without overhead ambient electrical lighting. Time-lapse observation of interior roller shades showed that existing shade control models overestimated the frequency of shade operation and underestimated the level of facade occlusion due to interior shades. Comparison of measured results to the daylighting objectives of the SFFB showed that available daylight enabled electrical lighting energy reduction in the perimeter zones but not in the open-plan core zones. The results extend existing knowledge regarding the amount of daylight illuminance acceptable for occupants to work comfortably without overhead electrical lighting and for the physical variables (and stimulus intensities) associated with visual discomfort and the operation of interior shading devices.
ISBN: 9781267228406Subjects--Topical Terms:
423442
Psychology, Behavioral.
Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants.
LDR
:03376nam 2200313 4500
001
377875
005
20130403093047.5
008
130522s2011 ||||||||||||||||| ||eng d
020
$a
9781267228406
035
$a
(UMI)AAI3498998
035
$a
AAI3498998
040
$a
UMI
$c
UMI
100
1
$a
Konis, Kyle Stas.
$3
506775
245
1 0
$a
Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants.
300
$a
420 p.
500
$a
Source: Dissertation Abstracts International, Volume: 73-07(E), Section: B, page: .
500
$a
Adviser: Charles C. Benton.
502
$a
Thesis (Ph.D.)--University of California, Berkeley, 2011.
520
$a
Commercial office buildings promoted as "sustainable," "energy efficient," "green," or "high performance" often reference use of daylight as a key strategy for reducing energy consumption and enhancing indoor environmental quality. However, buildings are rarely studied in use to examine if the design intent of a sufficiently daylit and a visually comfortable work environment is achieved from the perspective of building occupants or how occupant use of shading devices may affect electrical lighting energy reduction from photocontrols. This dissertation develops a field-based approach to daylighting performance assessment that pairs repeated measures of occupant subjective response using a novel desktop polling station device with measurements of the physical environment acquired using High Dynamic Range (HDR) imaging and other environmental sensors with the objective of understanding the physical environmental conditions acceptable to occupants. The approach is demonstrated with a 6-month field study involving (N=44) occupants located in perimeter and core open-plan office spaces in the San Francisco Federal Building (SFFB). Over 23,100 subjective assessments paired with physical measures were analyzed to develop models of visual discomfort and shade control and to examine the assumptions of existing daylighting performance indicators. The analysis found that existing daylight performance indicators overestimated the levels of daylight illuminance required by occupants to work comfortably without overhead ambient electrical lighting. Time-lapse observation of interior roller shades showed that existing shade control models overestimated the frequency of shade operation and underestimated the level of facade occlusion due to interior shades. Comparison of measured results to the daylighting objectives of the SFFB showed that available daylight enabled electrical lighting energy reduction in the perimeter zones but not in the open-plan core zones. The results extend existing knowledge regarding the amount of daylight illuminance acceptable for occupants to work comfortably without overhead electrical lighting and for the physical variables (and stimulus intensities) associated with visual discomfort and the operation of interior shading devices.
590
$a
School code: 0028.
650
4
$a
Psychology, Behavioral.
$3
423442
650
4
$a
Engineering, Architectural.
$3
506708
650
4
$a
Architecture.
$3
189426
690
$a
0384
690
$a
0462
690
$a
0729
710
2
$a
University of California, Berkeley.
$b
Architecture.
$3
423161
773
0
$t
Dissertation Abstracts International
$g
73-07(E)B.
790
1 0
$a
Benton, Charles C.,
$e
advisor
790
1 0
$a
Wickens, Thomas D.
$e
committee member
790
1 0
$a
Arens, Edward A.
$e
committee member
790
$a
0028
791
$a
Ph.D.
792
$a
2011
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3498998
筆 0 讀者評論
多媒體
多媒體檔案
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3498998
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入