語系:
繁體中文
English
日文
簡体中文
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
An automated temporal, amplitude, an...
~
Mikhail, Matthew.
An automated temporal, amplitude, and complexity-based comparison of commercial plethysmographs.
紀錄類型:
書目-電子資源 : Monograph/item
書名/作者:
An automated temporal, amplitude, and complexity-based comparison of commercial plethysmographs.
作者:
Mikhail, Matthew.
出版者:
Ann Arbor : : ProQuest Dissertations & Theses, , 2016
面頁冊數:
32 p.
附註:
Source: Dissertation Abstracts International, Volume: 78-03(E), Section: B.
Contained By:
Dissertation Abstracts International78-03B(E).
標題:
Medicine.
標題:
Engineering.
ISBN:
9781369090871
摘要、提要註:
The study of plethysmographic physiology has been limited by a lack of standardized and open plethysmographic hardware in clinical use. Fundamental differences in the processing of output between various devices obfuscate direct comparison, and the role played by physiology versus that by technology in the final viewable plethysmogram (PPG). This study proposes a largely automated, unbiased method for quantitatively comparing the outputs from proprietary pulse oximeter devices along three metrics: temporal delay, amplification, and complexity. It then applies these methods to the deconstruction of Masimo and Nellcor pulse oximeters.
An automated temporal, amplitude, and complexity-based comparison of commercial plethysmographs.
Mikhail, Matthew.
An automated temporal, amplitude, and complexity-based comparison of commercial plethysmographs.
- Ann Arbor : ProQuest Dissertations & Theses, 2016 - 32 p.
Source: Dissertation Abstracts International, Volume: 78-03(E), Section: B.
Thesis (M.D.)--Yale University, 2016.
The study of plethysmographic physiology has been limited by a lack of standardized and open plethysmographic hardware in clinical use. Fundamental differences in the processing of output between various devices obfuscate direct comparison, and the role played by physiology versus that by technology in the final viewable plethysmogram (PPG). This study proposes a largely automated, unbiased method for quantitatively comparing the outputs from proprietary pulse oximeter devices along three metrics: temporal delay, amplification, and complexity. It then applies these methods to the deconstruction of Masimo and Nellcor pulse oximeters.
ISBN: 9781369090871Subjects--Topical Terms:
373206
Medicine.
An automated temporal, amplitude, and complexity-based comparison of commercial plethysmographs.
LDR
:03606nmm a2200301 4500
001
476251
005
20170614101409.5
008
181208s2016 ||||||||||||||||| ||eng d
020
$a
9781369090871
035
$a
(MiAaPQ)AAI10153966
035
$a
AAI10153966
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Mikhail, Matthew.
$3
686843
245
1 3
$a
An automated temporal, amplitude, and complexity-based comparison of commercial plethysmographs.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2016
300
$a
32 p.
500
$a
Source: Dissertation Abstracts International, Volume: 78-03(E), Section: B.
500
$a
Adviser: Kirk Shelley.
502
$a
Thesis (M.D.)--Yale University, 2016.
520
$a
The study of plethysmographic physiology has been limited by a lack of standardized and open plethysmographic hardware in clinical use. Fundamental differences in the processing of output between various devices obfuscate direct comparison, and the role played by physiology versus that by technology in the final viewable plethysmogram (PPG). This study proposes a largely automated, unbiased method for quantitatively comparing the outputs from proprietary pulse oximeter devices along three metrics: temporal delay, amplification, and complexity. It then applies these methods to the deconstruction of Masimo and Nellcor pulse oximeters.
520
$a
With IRB approval, twelve healthy, awake subjects were studied. Each individual was attached simultaneously to a Nellcor ear probe and a Masimo finger device, and then instructed to perform incentive spirometry, Valsalva, and Mueller breathing maneuvers interspersed with normal breathing. For temporal delay and amplitude comparisons, the raw PPG data were first synchronized, then subsequently filtered into corresponding autonomic, respiratory, and cardiac frequency ranges. To assess the temporal delay, they were processed according to a sliding-window cross-correlation function, and the time shift of maximum correlation for each window was averaged, to determine a representative overall delay for each frequency range. For the amplitude analysis, the absolute value of the filtered data were integrated over a pre-determined time frame chosen at each frequency range, then divided to arrive at a ratio. These data were manually filtered to remove sequences corresponding to the noise artifact. Lastly, to assess pulse complexity, the raw data were converted from time-domain to frequency domain using digital Fast Fourier Transformation (dFFT), and an algorithm programmed to search for fundamental cardiac frequency, as well as the first five harmonic peaks. The dFFTs were then normalized according to fundamental frequency peak, and the ratios of the amplitude of each harmonic peak to the corresponding harmonic peak from the other device were generated.
520
$a
As outlined in this study, the Nellcor device temporally led the Masimo in the respiratory (p= 0.0338) and autonomic (p=0.0024) frequency ranges. Similarly, the Nellcor device demonstrated greater amplitude representation in those ranges as well (p<0.001). With regards to pulse complexity, however, the Masimo signal was better represented up to the first three harmonics (p<0.04). While the generalization of these results may be limited by the device placement, this study successfully presents a systematic method for comparing commercial hardware devices, paving the way for better understanding of this non-invasive modality.
590
$a
School code: 0265.
650
4
$a
Medicine.
$3
373206
650
4
$a
Engineering.
$3
372756
690
$a
0564
690
$a
0537
710
2 0
$a
Yale University.
$b
Medicine.
$3
686844
773
0
$t
Dissertation Abstracts International
$g
78-03B(E).
790
$a
0265
791
$a
M.D.
792
$a
2016
793
$a
English
筆 0 讀者評論
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入