Defect sizing using non-destructive ...
~
Kleinert, Wolf.
Defect sizing using non-destructive ultrasonic testing[electronic resource] :applying bandwidth-dependent DAC and DGS curves /
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
杜威分類號:
620.11274
書名/作者:
Defect sizing using non-destructive ultrasonic testing : applying bandwidth-dependent DAC and DGS curves // by Wolf Kleinert.
作者:
Kleinert, Wolf.
出版者:
Cham : : Springer International Publishing :, 2016.
面頁冊數:
xviii, 118 p. : : ill., digital ;; 24 cm.
Contained By:
Springer eBooks
標題:
Ultrasonic testing.
標題:
Materials Science.
標題:
Characterization and Evaluation of Materials.
標題:
Continuum Mechanics and Mechanics of Materials.
標題:
Operating Procedures, Materials Treatment.
ISBN:
9783319328362
ISBN:
9783319328348
內容註:
Preface -- Sizing Methods: Distance Gain Size (DGS) and Distance Amplitude Correction (DAC) -- A new approach to bring DGS and DAC close together -- Diagrams -- Perspectives.
摘要、提要註:
This book presents a precise approach for defect sizing using ultrasonics. It describes an alternative to the current European and American standards by neglecting their limitations. The approach presented here is not only valid for conventional angle beam probes, but also for phased array angle beam probes. It introduces an improved method which provides a significant productivity gain and calculates curves with high accuracy. Its content is of interest to all those working with distance gain size (DGS) methods or are using distance ampllitude correction (DAC) curves.
電子資源:
http://dx.doi.org/10.1007/978-3-319-32836-2
Defect sizing using non-destructive ultrasonic testing[electronic resource] :applying bandwidth-dependent DAC and DGS curves /
Kleinert, Wolf.
Defect sizing using non-destructive ultrasonic testing
applying bandwidth-dependent DAC and DGS curves /[electronic resource] :by Wolf Kleinert. - Cham :Springer International Publishing :2016. - xviii, 118 p. :ill., digital ;24 cm.
Preface -- Sizing Methods: Distance Gain Size (DGS) and Distance Amplitude Correction (DAC) -- A new approach to bring DGS and DAC close together -- Diagrams -- Perspectives.
This book presents a precise approach for defect sizing using ultrasonics. It describes an alternative to the current European and American standards by neglecting their limitations. The approach presented here is not only valid for conventional angle beam probes, but also for phased array angle beam probes. It introduces an improved method which provides a significant productivity gain and calculates curves with high accuracy. Its content is of interest to all those working with distance gain size (DGS) methods or are using distance ampllitude correction (DAC) curves.
ISBN: 9783319328362
Standard No.: 10.1007/978-3-319-32836-2doiSubjects--Topical Terms:
339165
Ultrasonic testing.
LC Class. No.: TA417.4
Dewey Class. No.: 620.11274
Defect sizing using non-destructive ultrasonic testing[electronic resource] :applying bandwidth-dependent DAC and DGS curves /
LDR
:01744nam a2200313 a 4500
001
450417
003
DE-He213
005
20161020151359.0
006
m d
007
cr nn 008maaau
008
161210s2016 gw s 0 eng d
020
$a
9783319328362
$q
(electronic bk.)
020
$a
9783319328348
$q
(paper)
024
7
$a
10.1007/978-3-319-32836-2
$2
doi
035
$a
978-3-319-32836-2
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
TA417.4
072
7
$a
TGMT
$2
bicssc
072
7
$a
TEC021000
$2
bisacsh
082
0 4
$a
620.11274
$2
23
090
$a
TA417.4
$b
.K64 2016
100
1
$a
Kleinert, Wolf.
$3
646532
245
1 0
$a
Defect sizing using non-destructive ultrasonic testing
$h
[electronic resource] :
$b
applying bandwidth-dependent DAC and DGS curves /
$c
by Wolf Kleinert.
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2016.
300
$a
xviii, 118 p. :
$b
ill., digital ;
$c
24 cm.
505
0
$a
Preface -- Sizing Methods: Distance Gain Size (DGS) and Distance Amplitude Correction (DAC) -- A new approach to bring DGS and DAC close together -- Diagrams -- Perspectives.
520
$a
This book presents a precise approach for defect sizing using ultrasonics. It describes an alternative to the current European and American standards by neglecting their limitations. The approach presented here is not only valid for conventional angle beam probes, but also for phased array angle beam probes. It introduces an improved method which provides a significant productivity gain and calculates curves with high accuracy. Its content is of interest to all those working with distance gain size (DGS) methods or are using distance ampllitude correction (DAC) curves.
650
0
$a
Ultrasonic testing.
$3
339165
650
1 4
$a
Materials Science.
$3
463741
650
2 4
$a
Characterization and Evaluation of Materials.
$3
463765
650
2 4
$a
Continuum Mechanics and Mechanics of Materials.
$3
463797
650
2 4
$a
Operating Procedures, Materials Treatment.
$3
463772
710
2
$a
SpringerLink (Online service)
$3
463450
773
0
$t
Springer eBooks
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-32836-2