語系:
繁體中文
English
日文
簡体中文
說明(常見問題)
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Corrosion-under-insulation (CUI) gui...
~
Winnik, S.
Corrosion-under-insulation (CUI) guidelines[electronic resource] /
紀錄類型:
書目-電子資源 : Monograph/item
杜威分類號:
621.8672
書名/作者:
Corrosion-under-insulation (CUI) guidelines/ edited by S. Winnik.
其他作者:
Winnik, S.
出版者:
Cambridge : : Woodhead Publishing,, c2015.
面頁冊數:
1 online resource : : col. ill.
附註:
Includes index.
標題:
Piping - Corrosion.
標題:
Insulation (Heat)
ISBN:
9780081007396 (electronic bk.)
ISBN:
0081007396 (electronic bk.)
ISBN:
9780081007143 (electronic bk.)
ISBN:
0081007140 (electronic bk.)
內容註:
Front Cover; Corrosion-Under-Insulation (CUI) Guidelines: Revised Edition; Copyright; Contents; Volumes in the EFC series; Introduction; Chapter 1: Introduction; 1.1 Purpose of document; References; Chapter 2:Economic consideration; 2.1 Statistical analysis; 2.2 Size of the issue; 2.2.1 Safety and integrity; 2.2.2 Environment; 2.2.3 Revenue or production loss; 2.2.4 Reputation; 2.2.5 Collateral damage cost; 2.2.6 On-line leak sealing cost; 2.2.7 Repair/replacement, fabrication, and installation costs; 2.2.8 Fitness for continued service; 2.2.9 On-stream inspection and NDE/NDT
摘要、提要註:
Corrosion-under-insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries. In the first edition of this book published in 2008, the EFC Working Parties WP13 and WP15 engaged together to provide guidelines on managing CUI with contributions from a number of European refining, petrochemical and offshore companies. The guidelines are intended for use on all plants and installation that contain insulated vessels, piping and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques and recommended best practice for mitigating CUI, including design of plant and equipment, coatings and the use of thermal spray techniques, types of insulation, cladding/jacketing materials and protection guards. The guidelines also include case studies. The original document first published in 2008 was very successful and provided an important resource in the continuing battle to mitigate CUI. Many members of the EFC corrosion community requested an update and this has taken between 18-24 months to do so. Hopefully this revised document will continue to serve the community providing a practical source of information on how to monitor and manage insulated systems.
電子資源:
click for full text
Corrosion-under-insulation (CUI) guidelines[electronic resource] /
Corrosion-under-insulation (CUI) guidelines
[electronic resource] /edited by S. Winnik. - Rev. ed. - Cambridge :Woodhead Publishing,c2015. - 1 online resource :col. ill. - Woodhead Publishing in materials. - Woodhead Publishing in materials..
Includes index.
Front Cover; Corrosion-Under-Insulation (CUI) Guidelines: Revised Edition; Copyright; Contents; Volumes in the EFC series; Introduction; Chapter 1: Introduction; 1.1 Purpose of document; References; Chapter 2:Economic consideration; 2.1 Statistical analysis; 2.2 Size of the issue; 2.2.1 Safety and integrity; 2.2.2 Environment; 2.2.3 Revenue or production loss; 2.2.4 Reputation; 2.2.5 Collateral damage cost; 2.2.6 On-line leak sealing cost; 2.2.7 Repair/replacement, fabrication, and installation costs; 2.2.8 Fitness for continued service; 2.2.9 On-stream inspection and NDE/NDT
Corrosion-under-insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries. In the first edition of this book published in 2008, the EFC Working Parties WP13 and WP15 engaged together to provide guidelines on managing CUI with contributions from a number of European refining, petrochemical and offshore companies. The guidelines are intended for use on all plants and installation that contain insulated vessels, piping and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques and recommended best practice for mitigating CUI, including design of plant and equipment, coatings and the use of thermal spray techniques, types of insulation, cladding/jacketing materials and protection guards. The guidelines also include case studies. The original document first published in 2008 was very successful and provided an important resource in the continuing battle to mitigate CUI. Many members of the EFC corrosion community requested an update and this has taken between 18-24 months to do so. Hopefully this revised document will continue to serve the community providing a practical source of information on how to monitor and manage insulated systems.
ISBN: 9780081007396 (electronic bk.)Subjects--Topical Terms:
658761
Piping
--Corrosion.Index Terms--Genre/Form:
336502
Electronic books.
LC Class. No.: TJ930 / .C67 2015
Dewey Class. No.: 621.8672
Corrosion-under-insulation (CUI) guidelines[electronic resource] /
LDR
:03149nmm a2200313 a 4500
001
457968
003
UIUdb
005
20160111132310.0
006
m o d
007
cr cn|||||||||
008
170113s2015 enka o 001 0 eng
020
$a
9780081007396 (electronic bk.)
020
$a
0081007396 (electronic bk.)
020
$a
9780081007143 (electronic bk.)
020
$a
0081007140 (electronic bk.)
035
$a
(OCoLC)ocn930703354
035
$a
16000118
040
$a
N
$b
eng
$c
N
$d
YDXCP
$d
N
$d
EBLCP
$d
OPELS
$d
UIU
$d
UIUdb
041
0
$a
eng
050
4
$a
TJ930
$b
.C67 2015
082
0 4
$a
621.8672
$2
23
245
0 0
$a
Corrosion-under-insulation (CUI) guidelines
$h
[electronic resource] /
$c
edited by S. Winnik.
250
$a
Rev. ed.
260
$a
Cambridge :
$b
Woodhead Publishing,
$c
c2015.
300
$a
1 online resource :
$b
col. ill.
490
1
$a
Woodhead Publishing in materials
500
$a
Includes index.
505
0
$a
Front Cover; Corrosion-Under-Insulation (CUI) Guidelines: Revised Edition; Copyright; Contents; Volumes in the EFC series; Introduction; Chapter 1: Introduction; 1.1 Purpose of document; References; Chapter 2:Economic consideration; 2.1 Statistical analysis; 2.2 Size of the issue; 2.2.1 Safety and integrity; 2.2.2 Environment; 2.2.3 Revenue or production loss; 2.2.4 Reputation; 2.2.5 Collateral damage cost; 2.2.6 On-line leak sealing cost; 2.2.7 Repair/replacement, fabrication, and installation costs; 2.2.8 Fitness for continued service; 2.2.9 On-stream inspection and NDE/NDT
520
$a
Corrosion-under-insulation (CUI) refers to the external corrosion of piping and vessels that occurs underneath externally clad/jacketed insulation as a result of the penetration of water. By its very nature CUI tends to remain undetected until the insulation and cladding/jacketing is removed to allow inspection or when leaks occur. CUI is a common problem shared by the refining, petrochemical, power, industrial, onshore and offshore industries. In the first edition of this book published in 2008, the EFC Working Parties WP13 and WP15 engaged together to provide guidelines on managing CUI with contributions from a number of European refining, petrochemical and offshore companies. The guidelines are intended for use on all plants and installation that contain insulated vessels, piping and equipment. The guidelines cover a risk-based inspection methodology for CUI, inspection techniques and recommended best practice for mitigating CUI, including design of plant and equipment, coatings and the use of thermal spray techniques, types of insulation, cladding/jacketing materials and protection guards. The guidelines also include case studies. The original document first published in 2008 was very successful and provided an important resource in the continuing battle to mitigate CUI. Many members of the EFC corrosion community requested an update and this has taken between 18-24 months to do so. Hopefully this revised document will continue to serve the community providing a practical source of information on how to monitor and manage insulated systems.
650
0
$a
Piping
$x
Corrosion.
$3
658761
650
0
$a
Insulation (Heat)
$3
586626
655
4
$a
Electronic books.
$2
local
$3
336502
700
1
$a
Winnik, S.
$q
(Stefan)
$3
658760
830
0
$a
Woodhead Publishing in materials.
$3
550119
856
4 0
$u
http://www.sciencedirect.com/science/book/9780081007143
$z
click for full text
筆 0 讀者評論
多媒體
多媒體檔案
http://www.sciencedirect.com/science/book/9780081007143
評論
新增評論
分享你的心得
Export
取書館別
處理中
...
變更密碼
登入